| Safety and prevention work is in the building and | | | | must be set, so can play on the intrusion alarm system, |
| residence, to take "air defense", "anti-matter", and | | | | security system management and the integrated |
| "technical defense" means the combination to protect | | | | management role. |
| the people in the production, life, personal and property | | | | (3) intrusion alarm system's basic requirements:fortified |
| safety, and production and living facilities from being | | | | area on the illegal invasion of real-time, reliable and |
| damaged . The main means of including in the | | | | accurate alarm and review, to avoid leakage, false |
| prevention of zones, security personnel (air defense), | | | | alarm.alarm system shall be a network, run |
| the construction to prevent equipment (anti-matter), the | | | | independently, with the output interface can be manual, |
| use of surveillance and communication technologies to | | | | automated approach to the wired or wireless |
| prevent the establishment of security system. Mainly | | | | communications systems outside alarm. 110 is reserved |
| by the security system video surveillance systems, | | | | with the local public security alarm center network |
| intrusion alarm systems, patrol system, access control | | | | interface.system should be able to press time, location, |
| (access control) system, car parking management | | | | regional any programming, or disarm defenses.should |
| system and the composition of visitors intercom | | | | be able to run the state of equipment and signal |
| systems. Its basic meaning is the integrated use of | | | | transmission line testing, fault alarm will be issued timely |
| computer network technology, communication | | | | and direct fault location.should have the ability to |
| technology, electronic information technology, safety | | | | prevent damage, destruction or when the detector |
| technology, an advanced, the economy, supporting the | | | | circuit is cut off, the system can be reported |
| safety and security system. | | | | immediately.the system can display alarm location, |
| Technical requirements 1. Video Surveillance System | | | | area, time, can print, record, filed for the record, and |
| (1) should be based on the management of security | | | | can provide video surveillance and alarm linkage, lights |
| technology to prevent the need for a place to be | | | | and lighting control interface signal.important part in the |
| monitored, location, access and other real-time, | | | | important area and send alarm signals, the system can |
| effective video surveillance, detection, transmission, | | | | sound the alarm on-site verification. |
| display and recording. And should have the linkage | | | | (4) intrusion alarm system can be divided into a |
| alarm and image review functions. | | | | multi-alarm alarm and two, should be based on the |
| (2) monitoring the screen display should be able to any | | | | complexity of the deployment region choose a |
| programming and can be automatically or manually | | | | different system. Usually advised to use a simple alarm |
| switch, monitor screen should display the camera | | | | system, complex multi-level alarm system should be |
| number, location, time and date of the necessary | | | | selected. An alarm system should be set one alarm |
| information. | | | | controller, multi-level alarm system should be set to a |
| (3) the monitoring system should be run from a | | | | concentration of more than one area alarm controller |
| network independent and can and intrusion alarm | | | | and the alarm controller and can strain network. |
| systems, access control (access control) system | | | | (5) should be adopted in the important region has |
| control linkage. When the alarm occurs, the alarm | | | | deployed more than two means of alarm detection |
| automatically to the site to review the images and | | | | and increase the reliability of alarm. Use of different |
| sound, can automatically switch to the specified site | | | | types of alarms in different locations such as: switching |
| images displayed on monitors and automatic recording. | | | | alarm, glass breaking sensor should be installed in the |
| (4) with the central control room should be able to | | | | doors and windows positions; passive infrared, Doppler |
| network, to achieve control room on the video | | | | microwave alarm suitable for installation in indoor; |
| surveillance system, centralized monitoring and | | | | active infrared, microwave alarm block device suitable |
| management. | | | | for installation in open air; voice alarm system should be |
| (5) technical requirements for video surveillance | | | | used in conjunction with other types of alarm; video |
| systems should refer to the relevant provisions of GA | | | | motion alarm and video surveillance systems for use. In |
| T367. | | | | such establishments, cashier, duty office position should |
| 2. Intrusion Alarm System (1) under the management | | | | be set up emergency alarm device. |
| of security technology to prevent the need for | | | | (6) alarm installation should pay attention to: switch |
| maximum security area of the illegal invasion, theft, | | | | alarm switch in accordance with the requirements of |
| vandalism and robbery, effective real-time detection | | | | different types of installation; infrared, microwave, |
| and alarms, and review by the alarm function. | | | | alarm system installed in the room should be kept to |
| (2) intrusion alarm systems are generally from the | | | | 2-2.4 m away from the wall or ceiling installation , and |
| detector, the regional controller and the alarm control | | | | the detection direction to maintain 45 ° -90 ° angle. |
| center composed of three parts. Usually a regional | | | | Outdoor enclosure with the detector should be used in |
| controller, the detector coupled with sound and light | | | | rain, fog, frost prevention, shading functionality. |
| alarm devices can constitute a simple alarm system. | | | | Intrusion alarm system technical requirements should |
| Systems that require higher security control center | | | | refer to GA/T368 in the regulations. |